Your machines already produce their own data. VECHR MES reads it over the protocols the equipment supports, attaches it to the relevant order, unit, and lot, then turns it into operational information you can use straight away.
Read live data from the machines you already own over OPC UA, MQTT and Modbus TCP. See OEE (Overall Equipment Effectiveness), MTTR and MTBF without a spreadsheet.
Today OEE is a spreadsheet built at month end.
With VECHR MES Availability, performance and quality, calculated live.
Today A dropped connection goes unnoticed.
With VECHR MES Connection health is visible, with automatic reconnect.
Today A breakdown is retyped into a work order.
With VECHR MES One click turns the event into a work order.
One machine, one source of information. Its configuration, live condition, history, and performance all sit in the same context.
| View | What it holds |
|---|---|
| General | Basic equipment information such as manufacturer, model, serial number, installation date, and capacity. |
| Monitor | Connection status and live data point values, including reading history so you can see previous conditions. |
| KPI | MTTR, MTBF, and availability for that equipment and for the resources beneath it. |
| OEE | Availability × Performance × Quality, displayed and trended continuously. |
| Data Points | Connection and data point configuration: protocol, tags, and read frequency. |
OEE is built from a full time hierarchy, from calendar time down to fully productive time.
| Protocol | Default port | What you configure |
|---|---|---|
| OPC UA | 4840 | Security policy and mode, application URI and name, session timeout, keep-alive, credentials, certificate. |
| MQTT | 1883 | Client ID, protocol version 3, 3.1.1 or 5, credentials, clean session, keep-alive, timeouts, reconnect period, certificate. |
| Modbus TCP | 502 | Unit ID, endianness, timeout, TLS, certificate. |
Every protocol has a retry policy. Data points can be defined one by one or bulk-loaded from CSV.
What automation and IT teams usually ask about connectivity.
No. VECHR MES connects over OPC UA, MQTT, and Modbus TCP. Equipment that already supports one of those protocols can be connected without replacing the PLCs or the SCADA (Supervisory Control and Data Acquisition) system already running.
The connection status changes immediately and the system attempts to reconnect automatically. Data in a degraded state still carries its quality flag, so it is never treated the same as valid data.
Yes. Availability, Performance, and Quality are computed from recorded equipment states and events, then displayed and trended over whatever time range you choose.